Pd Flowmeter for Horizontal Installation with Ce Approval
Model NO.: LSZ
Measuring Media: Liquid
Measuring Principle: Volumetric
Measurement Object: Closed Pipeline
Certification: JIS, DIN, GB, CE, ISO
Trademark: YINUO
Transport Package: Wooden Case
Specification: Size from 3/8inch to 16 inch
Origin: Shanghai, China.
HS Code: 9026100000
LSZ- Double-Rotator Flowmeter
General LSZ- Double-Rotator Flowmeter is the latest & international super-class volumetric-type flowmeter. It is a type of precise instrument measuring and controlling liquid flow in the pipeline, featuring high measurement precision, smooth running, free of pulsation, low noise, long service life and excellent adaptability to viscosity etc.. Therefore, the product has been widely used in various fields such as petroleum, chemical, metallurgy, electric power, shipping, traffic, dock, mine, thermal power, and foodstuff industries etc.. It is especially suitable for commercial trade measurement for crude oil, high condensation oil, crude oil with high water content, petroleum products, foodstuff and chemical solutions as well as measuring management and control of engineering automation. The codes and characters displayed on the flowmeter can be directly read locally. The photo-electric pulse converter equipped can output electric pulse(current) signals to the displaying instrument and computer for handling. Thus, the flow in the pipeline can be remotely controlled. Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Principle The measuring chamber of the double-rotator flowmeter consists of interior casing, a pair of helix rotators and top & bottom cover plates. These formed a cavity with known volume which can be used as the measuring unit for the flowmeter. The rotator of the flowmeter rotates under the tiny pressure difference between the inlet and outlet and continually sends the liquid at inlet to the outlet after cavity measurement(See Fig.2). The rotator transmits the rotating numbers to the counter by means of sealed coupling and driving system so that the total volume of the liquid passing the flowmeter can be directly displayed.
Picture 2: The Principle of LSZ- Flowmeter
                                              Â
                                                        Â
Inner measuring chamber
Chamber cases
Rotors
LSZ-Bi-rotator Flowmeter is a positive displacement meter utilized in the most demanding applications requiring accuracy, long life and ruggedness. It features two precisely machined rotating members known as helical rotors which rotate and mesh within the meter's interior housing in order to form a measuring chamber of known volume which may be used to accurately determine volumetric flow rate as a function of the rotors' velocity. As liquid enters the intake of the measurement element, two finely timed rotors divide the liquid into precise segments of known volume and return those segments to the flowing stream. During this transition, the rotation of the two rotors is directly proportional to volumetric throughput. Volume indication is determined by mechanical output gearing leading to electronic or mechanical  registration devices
Main Technical Parameters                                 Table:1
Nominal Dia. (mm)
8~400
Accuracy
±0.1%, ±0.2% and ±0.5%
Pressure loss
0~1000mPa.s<80Kpa  1000~20000mPa.2<150KPa
Nominal pressure
1.6, 2.5, 4.0, 6.4 MPa
Temperature range
-20°C ~ +80°C  +80°C ~ +150°C  +150°C ~ +250°C
Media viscosity
0~20000mPa.s
Ambient temperature
-40°C ~ +70°C
Connected flange
Can be custom-made
Photoelectric pulse(current)converter
Exd II CT6(Excluding acetylene)
Electronic meterhead
Exd II CT2-T6
Range of Flow       For Accuracy: 0.5% and 0.2%                                                            Table.2
 Nominal Dia. (mm)
Flow range m3/h
Pulse equivalent liter/pulse
0.32-0.8mPa.s
0.8-2mPa.s
2-5mPa.s
5-400mPa.s
400-2000mPa.s
2000-20000mPa.s
Gasoline/ liquefied gas
Kerosene
Light diesel
Crude oil, heavy oil
Hi-viscosity Liquid
Liquid with high water content & super-high viscosity liquid
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
0.5%
0.2%
15
0.6-3
Â
0.4-4
Â
0.4-4
Â
0.4-4
Â
0.3-2.4
Â
0.3-2.4
Â
0.001
25
3-8
Â
1.5-10
Â
1-10
Â
1-10
Â
1-8
Â
1-6
Â
 0.01 Â
40
8-20
8-20
2.7-22
5.5-22
2.5-25
4.4-22
2.5-25
4.4-22
2.1-18
4.2-18
1.5-12
3-12
50
9-36
15-36
4.5-36
9-36
4-40
7.2-36
4-40
7.2-36
2.8-24
6-24
2.2-18
4.5-18
80
20-80
32-80
10-80
20-80
9-90
16-80
9-90
16-80
6.5-56
14-56
5-40
10-40
   0.1
100
25-100
40-100
13-100
25-100
12-120
20-100
12-120
20-100
8.5-72
18-72
6.5-54
14-54
150
55-225
88-220
31-250
57-225
25-250
44-220
25-250
44-220
18-150
38-150
12-100
25-100
200
90-360
150-360
50-400
90-360
40-400
72-360
40-400
72-360
28-240
53-210
20-160
40-160
250
135-540
180-540
68-540
135-540
60-600
108-540
60-600
108-540
42-360
90-360
30-240
60-240
300
220-900
300-900
112-900
225-900
100-1000
180-900
100-1000
180-900
70-600
150-600
54-450
113-450
400
400-1600
550-1600
200-1600
400-1600
180-1800
320-1600
180-800
320-1600
130-1100
275-1100
90-750
180-750
Double-Rotator Flowmeter Accuracy: 0.1% Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Table.3
 Nominal Dia. (mm)
Flow range m3/h
Pulse equivalent liter/pulse
0.32-2 mPa.s Â
2-5 mPa.s
5-50mPa.s   500-400          mPa.s
400-2000 mPa.s
2000-20000 mPa.s
Gasoline/ liquefied gas
Kerosene
Light diesel
Crude oil,
heavy oil
Hi-viscosity Liquid
Liquid with high water content & super-high viscosity liquid
40
11-22
9-22
7.5-22
7.5-22
7.5-22
4-12
3.3-10
0.001
50
18-36
14.4-36
12-36
12-36
12-36
7.5-22
6-18
0.01
80
40-80
32-80
26.7-80
26.7-80
26.7-100
16-48
13-40
100
50-100
40-100
34-100
34-100
34-100
24-72
18-54
150
115-220
90-220
73-220
73-220
73-220
40-120
30-90
0.1
200
180-360
144-360
120-360
120-360
120-360
60-180
50-150
250
270-540
216-540
180-540
180-540
180-540
100-300
60-180
300
450-900
360-900
300-900
300-900
300-900
200-600
150-450
400
800-1600
640-1600
530-1600
530-1600
530-1600
400-1200
300-900
Double-Rotator Flowmeter-(Electron Meter head) Accuracy: 0.5%, 0.2%                                                   Table. 4
 Nominal Dia. (mm)
Flow range m3/h
Pulse equivalent liter/pulse
0.32-0.8mPa.s
0.8-2mPa.s
2-5mPa.s
5-4mPa.s
400-2000mPa.s
2000-20000mPa.s
Gasoline/ liquefied gas
Kerosene
Light diesel
Crude oil, heavy oil
Hi-viscosity Liquid
Liquid with high water content & super-high viscosity liquid