Submersible Pump for High Quality and Configuration- 4 Filters- 4 Flow Meters

Model NO.: TA2444LQ
Explosion-Proof Valve: Cjex14.0905
Flow Meter: Tatsuno / Tokheim
Nozzle: 1/2" and 3/4"
Large LCD Display: 886 or 664 Digits Display
Products: Gasoline, Diesel, Kerosene
Certificates: ISO9001:2008, EMS, Ohsas18001:2007
Trademark: TaiKong
Transport Package: Carton/Wooden Case
Specification: 1280mmx590mmx2385mm
Origin: China
HS Code: 84131100
Model:TB2444LQ(sbumersible model)

Mechanical : Combination pump, gear pump, submersible
Units:Taikong (self-production), Tokheim, Tatsuno
Products: Petrol, Kerosene, Diesel
Electrics: 886 or 664 Digits Display (amount, volume, pricing)
                 Battery-protected memory for security in the event of power failure
Surface colors and drawings: Can be optional
Certificates: ISO9001:2008, EMS, OHSAS18001:2007


Product Configuration:
Parts Numbers
Filter 4
Flow Measurement Meter 4
Explosion-proof valve 4
Metal Key Board 4
Nozzle 4
Large LCD Display 4

Optional function: vapor recovery, note printer, combination pump and gear pump.

Dimensions:1280mm×590mm×2385mm

Packing size:715mmx1450mmx2540mm


Function and configuration: 
1, Amounts of flow range and money can be set.
2, Decimal point can be set for displays as your requirement.
3, Anti-static electricity can be set as your requirement and keeping safety.
4, Voice broadcasting and note printer can be set as option.
5, Explosion-proof certificate: CJEx14.0905
6, ISO9001 certificate
7, products (petrol, diesel, kerosene).
8, Emergency cut-off button
9, Repeating Accuracy: ≤ 0.03%
10 , Input vacuum≥54KPa, output vacuum≤0.3Mpa.
11, Nozzles can be shut off when tanker is full.
12, Record for 500 times operation.
13, Ports can be reserved as upgrading.
14, Internet connection can be set or internet ports are reserved. 
15, 3 kinds of pumps can be set as your requirements (Gear pump, combination pump,
   submersible pump)

Technical parameters 
Flow range 5L/min ~ 50L/min(±10%)
Large flow10L/min ~ 100L/min(±10%)
Oil-gas recovery, maximum flow 40L/min(±10%)
Power supply Common series:AC380V+10% ,-15%(50Hz±1Hz)
single phase series :AC220V+10% ,-15%(50Hz±1Hz)
Motor rated power 750W ( /1000W )
Inlet oil pressure Oil-submerged pump series≤0.3MPa
Maximum permissible errors ±0.30%
Environment temperature -25ºC~+55ºC( Low temperature regions:-40ºC~+55ºC)
Relative humidity ≤95%
Oil-gas recovery rate 95% ~ 105%(Oil-gas recovery)
Price range 1.00 ~ 99.99Yuan/liter
Register range Amount: 0.01 ~ 9999.99Yuan
Volume: 0.01 ~ 9999.99liter
Totalizer range Amount: 0.01 ~ 99999999.99Yuan
Volume: 0.01 ~ 99999999.99liter
Display time after power failure ≥15Min
Noise ≤80dB(A)

Why taking Aerospace XinYang?
1, Aerospace XinYang was founded in 1979, and especially working in field of fuel dispenser for
   37 years. Time of working in this field gives us plenty of experiences to fuel dispenser.
2, We have the most market shares in Chinese market. Aerospace XinYang is also one of    
    suppliers
 for PetroChina and Sinopec ,which have strictest standards in China.
3, We have own teams from design, produce,assemble to packing processes. We are working
    strictly by ISO9001. Identification of Site Existence and Business Operations by Bureau Veritas
    have been passed for global market.
 
Customer's privileges:
1, You can have your own patterns or colors on the machine as your needs.
2, You can be our agent or distributor in your market.
  OEM is available.
3, Parts position on surface can be down as your needs, for example: set oil indicators on the
  front or on the side; nozzle holder on the front or on the side.
Configuration of each model
Model  Pump    Nozzle      Flow meter Keyboard   Display
2211 1 2 1 2 2
2212 1 2 2 2 4
2222 2 2 2 2 4
2422 2 4 2 4 4
2444 4 4 4 4 4
2424 2 4 4 4 4
3111 1 1 1 1 2
3212 1 2 2 2 4
3222 2 2 2 2 4
 


 
 

Inclined plate clarifier

Feiyiya Inclined Plate Clarifiers Use Gravity & Innovative Engineering

A gravity clarifier is the most economical method of removing solids from liquids, using natural gravity as the source of energy and it is free. A clarifier simply provides a non-turbulent zone where heavier than liquid solids, suspended by turbulence, are given sufficient time to settle to a quiescent surface. The HEI inclined plate clarifiers are compact units with multiple layers of settling area utilizing less than 25% of the floor space required by conventional clarifiers.

Principle of Clarifiers

A particle carried forward by the velocity of the liquid flow must settle at a rate that allows it to reach the bottom before passing through the clarifer. Thus, particles beginning at a point [a" must traverse some route lying between ab and ab` in order to avoid being carried over the outlet.

1701680328799

If V is the horizontal velocity of the liquid, S the solids particle vertical settling velocity, L the length of the settling device, and D its depth, then particles entering at point A will settle to the bottom of the device only if V does not exceed: S(L/D)Since Vmax / S = L / D then, Vmax = S (L / D)

Therefore, the velocity at which a horizontal clarifying device may be operated successfully is directly proportional to its length and inversely proportional to its depth.

This analysis applies to multiple horizontal plate units also. The spacing between plates is usually a few inches as opposed to a depth of several feet in a horizontal tank; therefore, [settling-out" times are dramatically reduced. The flow must be non-turbulent to prevent settled solids from being re-entrained within the moving liquid. Small plate spacing and a large surface area permits laminar flow at higher velocities than large horizontal tanks would allow.


Horizontal clarifying devices become self-flushing if they are inclined at an angle which exceeds the angle of repose of the settled solids. In such cases, flow enters the lower end of the device where settling particles move to the floor eventually sliding back out the entrance. Clear effluent leaves the top of the device.
1701680354228However, when the device is inclined, the furthest settling particles no longer fall through distance D but some longer distance D`. This new longer settling distance D` is related to D by the relation: D = D` cos Ø.

Theta [Ø" is the angle, the device is inclined to the horizontal plane. Thus settling distance is increased by the factor: 1/cos Ø In the case where Ø = 60º, 1/cos Ø = 2.

The maximum settling distance is twice the distance between the plates. It is apparent then that the lower the angle of inclination, the smaller the settling distance. However, the angle of inclination must exceed the angle of repose of the solids to be separated. The previous equation may be modified to express the cosine of an inclined plate clarifying system as:
Vmax = L / (D / cosØ) (s) = L·cosØ / D (s)


Inclined Plate Clarifiers
A reduction of the required floor space is acquired by diminishing the separation between the horizontal plates to a few inches and stacking the settling surfaces. Inclining the plates to provide self flushing, 45º for heavy particles and 60º for light particles, reduces the available horizontal projected area (effective settling area) by a factor equivalent to the cosine of the angle. The surface area diagram (below) graphically compares the floor space requirements of an HEI inclined plate clarifier with the equivalent horizontal projected settling area.

Settling Rate
The settling rate for a specific solids should be determined by standard laboratory tests. Light particles, such as metal hydroxides, usually require a design parameter of 0.25 – 0.50 gallons per minute per square foot of horizontal projected area. These low density solids require the inclined plates to be set at a 60º angle to induce the particles to slide down the plate. Heavier particles (such as sand that easily flow) will readily slide from plates set at a 45º angle.

1701221536993
Maximum flow rate of an inclined plate clarifier is based on the flow rate per unit of a horizontally projected surface area. Retention time in the clarifier is not a design criteria. However, attaining optimum performance requires the prudent design to recognize several additional, very important factors.

Inclined plate clarifier, Lanmei inclined plate clarifier, Inclined Tube Settler,High-Efficiency Inclined Tube

Wuxi Feiyiya Environmental Protection Technology Co., Ltd. , https://www.fefinegrille.com